Getting Ready for Energy-Efficient Networking B. Claise Internet-Draft Huawei Intended status: Informational L. M. Contreras Expires: 18 November 2025 Telefonica J. Lindblad For.Eco M. Palmero Cisco Systems, Inc. E. Stephan Orange Q. Wu Huawei 17 May 2025 Framework for Energy Efficiency Management draft-belmq-green-framework-01 Abstract Recognizing the urgent need for energy efficiency, this document specifies a management framework focused on devices and device components within, or connected to, interconnected systems. The framework aims to enable energy usage optimization and ensure interoperability across diverse systems. Leveraging data from existing use cases, it delivers actionable metrics to support effective energy management and informed decision-making. Furthermore, the framework proposes mechanisms for representing and organizing timestamped telemetry data using YANG models and metadata, enabling transparent and reliable monitoring. This structured approach facilitates improved energy efficiency through consistent energy management practices. About This Document This note is to be removed before publishing as an RFC. The latest revision of this draft can be found at https://marisolpalmero.github.io/draft-belm-green-framework/draft- belmq-green-framework.html. Status information for this document may be found at https://datatracker.ietf.org/doc/draft-belmq-green- framework/. Discussion of this document takes place on the Getting Ready for Energy-Efficient Networking mailing list (mailto:green@ietf.org), which is archived at https://mailarchive.ietf.org/arch/browse/green/. Subscribe at https://www.ietf.org/mailman/listinfo/green/. Claise, et al. Expires 18 November 2025 [Page 1] Internet-Draft Framework for Energy Efficiency Manageme May 2025 Source for this draft and an issue tracker can be found at https://github.com/marisolpalmero/draft-belm-green-framework. Status of This Memo This Internet-Draft is submitted in full conformance with the provisions of BCP 78 and BCP 79. Internet-Drafts are working documents of the Internet Engineering Task Force (IETF). Note that other groups may also distribute working documents as Internet-Drafts. The list of current Internet- Drafts is at https://datatracker.ietf.org/drafts/current/. Internet-Drafts are draft documents valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet-Drafts as reference material or to cite them other than as "work in progress." This Internet-Draft will expire on 18 November 2025. Copyright Notice Copyright (c) 2025 IETF Trust and the persons identified as the document authors. All rights reserved. This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (https://trustee.ietf.org/ license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Revised BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Revised BSD License. Table of Contents 1. TO DO . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1. Terminology . . . . . . . . . . . . . . . . . . . . . . . 4 3. Motivation . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.1. Impact on Energy Metrics . . . . . . . . . . . . . . . . 6 3.2. Current Device Readiness . . . . . . . . . . . . . . . . 6 3.3. Why Now? . . . . . . . . . . . . . . . . . . . . . . . . 7 4. Reference Model . . . . . . . . . . . . . . . . . . . . . . . 7 4.1. Power over Ethernet . . . . . . . . . . . . . . . . . . . 10 4.1.1. Single Power Supply with Multiple Devices . . . . . . 12 5. Conventions and Definitions . . . . . . . . . . . . . . . . . 14 6. Security Considerations . . . . . . . . . . . . . . . . . . . 14 Claise, et al. Expires 18 November 2025 [Page 2] Internet-Draft Framework for Energy Efficiency Manageme May 2025 7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 14 8. Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . 14 9. References . . . . . . . . . . . . . . . . . . . . . . . . . 15 9.1. Normative References . . . . . . . . . . . . . . . . . . 15 9.2. Informative References . . . . . . . . . . . . . . . . . 15 10. Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . 15 11. References . . . . . . . . . . . . . . . . . . . . . . . . . 15 11.1. Normative References . . . . . . . . . . . . . . . . . . 15 11.2. Informative References . . . . . . . . . . . . . . . . . 15 Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . . 16 1. TO DO * IEC60050 reference needs a new URL 2. Introduction In reference to [I-D.stephan-green-use-cases], analyzing use cases such as the "Incremental Application of the GREEN Framework" and "Consideration of other domains for obtention of end-to-end metrics", it reveals the critical need for a structured approach to transitioning network devices' management towards energy-efficient operations. The framework is essential for: * Standardization: Ensuring consistent practices across different devices and network segments to facilitate interoperability. * Efficient Energy Management: Providing guidelines to identify inefficiencies and implement improvements. * Scalability: Offering solutions that accommodate growing network demands and complexity. * Cost Reduction: Optimizing energy usage to lower operational costs and extend equipment lifecycles. * Competitiveness: Enabling organizations to maintain a competitive infrastructure through enhanced sustainability. * Environmental Impact: Supporting broader sustainability initiatives by reducing carbon footprints. * Simplified Implementation: Streamlining the deployment of energy- efficient measures to minimize service disruptions. * Security: Protecting sensitive operations related to power states and consumption. Claise, et al. Expires 18 November 2025 [Page 3] Internet-Draft Framework for Energy Efficiency Manageme May 2025 This document defines an Energy Management framework for devices within, or connected to, communication networks, for the use cases described in [I-D.stephan-green-use-cases]. The devices, or the components of these devices (such as line cards, fans, and disks), can then be monitored and controlled. Monitoring includes measuring power, energy, demand, and attributes of power. Energy Control can be performed by setting a device's or component's state. The devices monitored by this framework can be either of the following: - consumers of energy (such as routers and computer systems) and components of such devices (such as line cards, fans, and disks) - producers of energy (like an uninterruptible power supply or renewable energy system) and their associated components (such as battery cells, inverters, or photovoltaic panels) 2.1. Terminology The following terms are defined in [I-D.draft-bclp-green-terminology] and EMAN Framework [RFC7326]: Energy, Power, Energy Management, Energy Monitoring, Energy Control. The following terms are defined in EMAN Framework [RFC7326], and cut/ paste here for completeness: Energy Management System (EnMS) An Energy Management System is a combination of hardware and software used to administer a network, with the primary purpose of Energy Management. Claise, et al. Expires 18 November 2025 [Page 4] Internet-Draft Framework for Energy Efficiency Manageme May 2025 NOTES: 1. An Energy Management System according to [ISO50001] (ISO-EnMS) is a set of systems or procedures upon which organizations can develop and implement an energy policy, set targets and action plans, and take into account legal requirements related to energy use. An ISO-EnMS allows organizations to improve energy performance and demonstrate conformity to requirements, standards, and/or legal requirements. 2. Example ISO-EnMS: Company A defines a set of policies and procedures indicating that there should exist multiple computerized systems that will poll energy measurements from their meters and pricing / source data from their local utility. Company A specifies that their CFO (Chief Financial Officer) should collect information and summarize it quarterly to be sent to an accounting firm to produce carbon accounting reporting as required by their local government. 3. For the purposes of EMAN, the definition herein is the preferred meaning of an EnMS. The definition from [ISO50001] can be referred to as an ISO Energy Management System (ISO-EnMS). Device A device is a piece of electrical or non-electrical equipment. Reference: Adapted from [IEEE100]. Component A component is a part of electrical or non-electrical equipment (device). Reference: Adapted from [TMN]. Meter (Energy Meter) A meter is a device intended to measure electrical energy by integrating power with respect to time. Reference: Adapted from [IEC60050]. Power Inlet A power inlet (or simply "inlet") is an interface at which a device or component receives energy from another device or component. Power Outlet A power outlet (or simply "outlet") is an interface at which a device or component provides energy to another device or component. Power Interface A Power Interface is a power inlet, outlet, or both. Claise, et al. Expires 18 November 2025 [Page 5] Internet-Draft Framework for Energy Efficiency Manageme May 2025 Power State A Power State is a condition or mode of a device (or component) that broadly characterizes its capabilities, power, and responsiveness to input. Reference: Adapted from [IEEE1621]. Power State Set A Power State Set is a collection of Power States that comprises a named or logical control grouping. Energy Object An Energy Object represents a piece of equipment that is part of, or attached to, a communications network that is monitored or controlled or that aids in the management of another device for Energy Management. 3. Motivation 3.1. Impact on Energy Metrics The framework will significantly enhance the creation of energy metrics with actionable insights by: * Standardizing Metrics: Establishing consistent measurement protocols for energy consumption and efficiency. * Enhancing Data Collection: Facilitating comprehensive monitoring and data aggregation across devices. * Supporting Real-time Monitoring: Enabling dynamic tracking and immediate optimization of energy usage. * Integration Across Devices: Ensuring interoperability for network- wide data analysis. * Providing Actionable Insights: Translating raw data into meaningful information for decision-making. 3.2. Current Device Readiness While many modern networking devices have basic energy monitoring capabilities, these are often proprietary. The framework will define requirements to enhance these capabilities, enabling standardized metric production and meaningful data contributions for energy management goals. Claise, et al. Expires 18 November 2025 [Page 6] Internet-Draft Framework for Energy Efficiency Manageme May 2025 3.3. Why Now? The decision to define the framework now, rather than later, is driven by: * Immediate Benefits: Start realizing cost savings, reduced carbon footprints, and improved efficiencies. * Rapid Technological Advancements: Aligning the framework with current technologies to prevent obsolescence. * Increasing Energy Demands: Mitigating the impact of growing energy consumption on costs and sustainability. * Regulatory Pressure: Preparing for compliance with existing and anticipated sustainability regulations. * Competitive Advantage: Positioning organizations as leaders in sustainability and innovation. * Foundational Work Ready: Building on the use cases and requirements established in Phase I. * Proactive Risk Management: Minimizing risks associated with energy costs and environmental factors. * Facilitate Future Innovations: Creating a platform for continuous improvements and adaptations. * Stakeholder Engagement: Ensuring diverse perspectives are reflected for broader adoption. In conclusion, establishing the framework for energy efficiency management now is strategic and timely, leveraging the current momentum of use cases and requirements to drive meaningful progress in energy efficiency management. Delaying its development could result in missed opportunities for immediate benefits, increased costs, and challenges in adapting to future technological and regulatory landscapes. 4. Reference Model The framework introduces the concept of a Power Interface that is analogous to a network interface. A Power Interface is defined as an interconnection among devices where energy can be provided, received, or both. Claise, et al. Expires 18 November 2025 [Page 7] Internet-Draft Framework for Energy Efficiency Manageme May 2025 The most basic example of Energy Management is a single device reporting information about itself. In many cases, however, energy is not measured by the device itself but is measured upstream in the power distribution tree. For example, a Power Distribution Unit (PDU) may measure the energy it supplies to attached devices and report this to an Energy Management System. Therefore, devices often have relationships to other devices or components in the power network. An Energy Management System (EnMS) generally requires an understanding of the power topology (who provides power to whom), the Metering topology (who meters whom), and the potential Aggregation (who aggregates values of others). The relationships build on the Power Interface concept. The different relationships among devices and components, as specified in this document, include power source, Metering, and Aggregation Relationships. The framework does not cover non-electrical equipment, nor does it cover energy procurement and manufacturing. ~~~~ {: #reference-model title="GREEN Reference Model"} +-------------------------------------------------------------------- + | | | (3) Network Domain Level | | | +----------------------------- ---------------------------------------+ (a) (b) (c) Inventory Monitor +- DataSheets/DataBase and/or via API Of identity Energy | Metadata and other device/component and Capability Efficiency | /network related information: ^ ^ | | | | .Power/Energy related metrics | | | .information | | | .origin of Energy Mix | | | .carbon aware based on location | | | | | | | | | | | v +----------------------------------- ---------------------------------+ | | | (2) controller (collection, compute and aggregate?) | | | +-------------------------------------- ------------------------------+ ^ ^ ^ | (d) | (e) | (f) | | Inventory | Monitor power | Control | | Capability | Proportion | (Energy saving | | | Energy efficiency| Functionality | | | ratio, power | Localized mgmt/ | | | consumption, | network wide mgmt) | | | etc) | | | | | | v +------------------------------------------------- -------------------+ | | | (1) Device/Component | | | | +---------+ +-----------+ +----------------+ +----------------+ | | | (I) | | (II) | | (III) | | (IV) | | | | | | | | Legacy | | 'Attached'(PoE | | | | Device | | Component | | Device | | end Point) | | | | | | | | | | | | | +---------+ +-----------+ +----------------+ +----------------+ | +---------------------------- ----------------------------------------+ Claise, et al. Expires 18 November 2025 [Page 8] Internet-Draft Framework for Energy Efficiency Manageme May 2025 The main elements in the framework are as follows: (a),(d) Discovery and Inventory (b),(c) GREEN Metrics (b),(e) Monitor energy efficiency (f) Control Energy Saving The monitoring interface (e) obviously monitor more aspects than just power and energy, (for example traffic monitoring) but this is not covered in the framework. Note that this framework specificies logical blocks, however, the Energy Efficiency Management Function might be implemented inside the device or in the controller or a combination of both. ## Typical Power Topologies The following reference model describes physical power topologies that exist in parallel with a communication topology. While many more topologies can be created with a combination of devices, the following are some basic ones that show how Energy Management topologies differ from Network Management topologies. Only the controller, devices and components, are depicted here, as the Network Domain Level remains identical. NOTE: "###" is used to denote a transfer of energy. "- >" is used to denote a transfer of information. ### Basic Power Supply This covers the basic example of router connected to Power Outlet in the wall. Note that in typical deployements, there are no interface (d), (e), and (f) for that Power Outlet. If the router can not monitor its power, energy, demand, a physical meter is required (see next section). ~~~~ {: #basic-power title="Reference Model Example: Basic Power Supply"} +--------------------------------------------------------------------+ | | | (3) Network Domain Level | | | +--------------------------------------------------------------------+ (a) (b) (c) Inventory Monitor +- DataSheets/DataBase and/or via API Of identity Energy | Metadata and other device/component Claise, et al. Expires 18 November 2025 [Page 9] Internet-Draft Framework for Energy Efficiency Manageme May 2025 and Capability Efficiency | /network related information: ^ ^ | | | | .Power/Energy related metrics | | | .information | | | .origin of Energy Mix | | | .carbon aware based on location | | | | | | | | | | | v +--------------------------------------------------------------------+ | | | (2) controller (collection, compute and aggregate?) | | | +--------------------------------------------------------------------+ ^ ^ ^ | ^ ^ ^ | | | | | | | | | (d) (e) (f) (d) (e) (f) | | | | | | | | | | v | | v +--------------+ +------------------+ | | | | | Power Supply |############| Device/Component | | | | | +--------------+ +------------------+ 4.1. Power over Ethernet This covers the example of a switch port (Power Outlet) the provides energy with Power over Ethernet (PoE) to a PoE end points (camera, access port, etc.). ~~~~ {: #power-ethernet title="Reference Model Example: Power over Ethernet"} +-------------------------------------------------------------------- + | | | (3) Network Domain Level | | | +----------------------------- ---------------------------------------+ (a) (b) (c) Inventory Monitor +- DataSheets/DataBase and/or via API Of identity Energy | Metadata and other device/component and Capability Efficiency | /network related information: ^ ^ | | | | .Power/Energy related metrics | | | .information | | | .origin of Energy Mix | | | .carbon aware based on location | | | | | | | | | | | v +----------------------------------- ---------------------------------+ | | | (2) controller (collection, compute and aggregate?) | | | +-------------------------------------- ------------------------------+ ^ ^ ^ | ^ ^ ^ | | | | | | | | | (d) Claise, et al. Expires 18 November 2025 [Page 10] Internet-Draft Framework for Energy Efficiency Manageme May 2025 (e) (f) (d) (e) (f) | | | | | | | | | | v | | v +--------------+ +----------------+ | | | | | Device |############| PoE End Point | | (switch) | | | | | | | +--------------+ +----------------+ The most important issue in such a topology is to avoid the double-counting in the Energy Management System (EnMS). The switch port, via its Power Outlet, reports the Energy transmitted, while the PoE End Point, via its Power Inlet, reports its Energy consumed. Those two values are identical. Without the knowledge of this specific topology, that is the Power Source Relationship between the two Energy Objects, the EnMS will double-count the Energy consumed by those two devices. A Power Source Relationship is a relationship where one Energy Object provides power to one or more Energy Objects. ### Physical Meter This covers the basic example of device connected to wall Power Outlet, with a Physical Meter placed in the wall Power Outlet, because the device can not monitor its power, energy, demand. ~~~~ {: #physical-meter title="Reference Model Example: Physical Meter"} +--------------------------------------------------------------------+ | | | (3) Network Domain Level | | | +--------------------------------------------------------------------+ (a) (b) (c) Inventory Monitor +- DataSheets/DataBase and/or via API Of identity Energy | Metadata and other device/component and Capability Efficiency | /network related information: ^ ^ | | | | .Power/Energy related metrics | | | .information | | | .origin of Energy Mix | | | .carbon aware based on location | | | | | | | | | | | v +--------------------------------------------------------------------+ | | | (2) controller (collection, compute and aggregate?) | | | +--------------------------------------------------------------------+ ^ ^ ^ | ^ ^ ^ | Claise, et al. Expires 18 November 2025 [Page 11] Internet-Draft Framework for Energy Efficiency Manageme May 2025 | | | | | | | | (d) (e) (f) (d) (e) (f) | | | | | | | | | | v | | v +--------------+ +----------------+ +------------------+ | | | | | | | Power Supply |###| Physical Meter |###| Device/Component | | | | | | | +--------------+ +----------------+ +------------------+ When the EnMS discovers the physical meter, it must know which for which Energy Object(s) it measures power or energy. This is the Metering Relatonship. A Metering Relationship is a relationship where one Energy Object measures power, energy, demand, or Power Attributes of one or more other Energy Objects. The Metering Relationship gives the view of the Metering topology. Physical meters can be placed anywhere in a power distribution tree. For example, utility meters monitor and report accumulated power consumption of the entire building. Logically, the Metering topology overlaps with the wiring topology, as meters are connected to the wiring topology. A typical example is meters that clamp onto the existing wiring. 4.1.1. Single Power Supply with Multiple Devices This covers the example of a smart PDU that provides energy to a series of routers in a rack. ~~~~ {: #multiple-devices title="Reference Model Example: Single Power Supply with Multiple Devices"} +-------------------------------------------------------------------- + | | | (3) Network Domain Level | | | +----------------------------- ---------------------------------------+ (a) (b) (c) Inventory Monitor +- DataSheets/DataBase and/or via API Of identity Energy | Metadata and other device/component and Capability Efficiency | /network related information: ^ ^ | | | | .Power/Energy related metrics | | | .information | | | .origin of Energy Mix | | | .carbon aware based on location | | | | | | | | | | | v +----------------------------------- ---------------------------------+ | | | (2) controller (collection, compute and aggregate?) | | | +-------------------------------------- ------------------------------+ ^ ^ ^ | ^ ^ ^ | | | | | | | | | (d) (e) (f) (d) (e) (f) ... N | | | | | | | | | | v | | v +--------------+ +--------------------+ | | | | | Power Supply |############| Device/Component 1 | | (Smart PDU) | # | | | | Claise, et al. Expires 18 November 2025 [Page 12] Internet-Draft Framework for Energy Efficiency Manageme May 2025 # +--------------------+ +--------------+ # # # +--------------------+ # | | ##########| Device/Component 2 | # | | # +--------------------+ # # +--------------------+ # | | #######| Device/Component N | | | +--------------------+ ### Multiple Power Supplies with Single Device ~~~~ {: #multiple-power title="Reference Model Example: Multiple Power Supplies with Single Device"} +--------------------------------------------------------------------+ | | | (3) Network Domain Level | | | +--------------------------------------------------------------------+ (a) (b) (c) Inventory Monitor +- DataSheets/DataBase and/or via API Of identity Energy | Metadata and other device/component and Capability Efficiency | /network related information: ^ ^ | | | | .Power/Energy related metrics | | | .information | | | .origin of Energy Mix | | | .carbon aware based on location | | | | | | | | | | | v +--------------------------------------------------------------------+ | | | (2) controller (collection, compute and aggregate?) | | | +--------------------------------------------------------------------+ ^ ^ ^ | ^ ^ ^ | ^ ^ ^ | | | | | | | | | | | | | (d) (e) (f) (d) (e) (f) (d) (e) (f) | | | | | | | | | | | | | | v | | v | | v +----------------+ +------------------+ +----------------+ | | | | | | | Power Supply 1 |######| Device/Component |######| Power Supply 2 | | | | | | | +----------------+ +------------------+ +----------------+ Claise, et al. Expires 18 November 2025 [Page 13] Internet-Draft Framework for Energy Efficiency Manageme May 2025 5. Conventions and Definitions The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all capitals, as shown here. 6. Security Considerations Resiliency is an implicit use case of energy efficiency management which comes with numerous security considerations : Controlling Power State and power supply of entities are considered highly sensitive actions, since they can significantly affect the operation of directly and indirectly connected devices. Therefore, all control actions must be sufficiently protected through authentication, authorization, and integrity protection mechanisms. Entities that are not sufficiently secure to operate directly on the public Internet do exist and can be a significant cause of risk, for example, if the remote control functions can be exercised on those devices from anywhere on the Internet. The monitoring of energy-related quantities of an entity as addressed can be used to derive more information than just the received and provided energy; therefore, monitored data requires protection. This protection includes authentication and authorization of entities requesting access to monitored data as well as confidentiality protection during transmission of monitored data. Privacy of stored data in an entity must be taken into account. Monitored data may be used as input to control, accounting, and other actions, so integrity of transmitted information and authentication of the origin may be needed. 7. IANA Considerations This document has no IANA actions. 8. Acknowledgments This framework takes into account concepts from the Energy MANagement (EMAN) Framework [RFC7326], authors by John Parello, Benoit Claise, Brad Schoening, and Juergen Quittek. The contribution of Luis M. Contreras to this document has been supported by the Smart Networks and Services Joint Undertaking (SNS JU) under the European Union's Horizon Europe research and innovation projects 6Green (Grant Agreement no. 101096925) and Exigence (Grant Agreement no. Claise, et al. Expires 18 November 2025 [Page 14] Internet-Draft Framework for Energy Efficiency Manageme May 2025 101139120). 9. References 9.1. Normative References 9.2. Informative References 10. Appendix This appendix should be removed when the initial set of GREEN WG documents will be stable 11. References 11.1. Normative References [I-D.draft-bclp-green-terminology] Liu, P. C., Boucadair, M., Wu, Q., Contreras, L. M., and M. Palmero, "Terminology for Energy Efficiency Network Management", Work in Progress, Internet-Draft, draft-bclp- green-terminology-01, 23 April 2025, . [I-D.stephan-green-use-cases] Stephan, E., Palmero, M., Claise, B., Wu, Q., Contreras, L. M., and C. J. Bernardos, "Use Cases for Energy Efficiency Management", Work in Progress, Internet-Draft, draft-stephan-green-use-cases-01, 16 May 2025, . [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997, . [RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC 2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174, May 2017, . 11.2. Informative References [IEC60050] IEC, "Power Utility Automation", 11 December 2000, . Claise, et al. Expires 18 November 2025 [Page 15] Internet-Draft Framework for Energy Efficiency Manageme May 2025 [IEEE100] IEEE, "The Authoritative Dictionary of IEEE Standards Terms", 11 December 2000, . [IEEE1621] IEEE, "Standard for User Interface Elements in Power Control of Electronic Devices Employed in Office/Consumer Environments, IEEE 1621", December 2004. [RFC7326] Parello, J., Claise, B., Schoening, B., and J. Quittek, "Energy Management Framework", RFC 7326, DOI 10.17487/RFC7326, September 2014, . [TMN] "International Telecommunication Union, "TMN management functions"", February 2000, . Authors' Addresses Benoit Claise Huawei Email: benoit.claise@huawei.com Luis M. Contreras Telefonica Email: luismiguel.contrerasmurillo@telefonica.com Jan Lindblad For.Eco Email: jan.lindblad+ietf@for.eco Marisol Palmero Cisco Systems, Inc. Email: mpalmero@cisco.com Emile Stephan Orange Email: emile.stephan@orange.com Qin Wu Huawei Email: bill.wu@huawei.com Claise, et al. Expires 18 November 2025 [Page 16]